WKZT2-30 2 Axis Rate Table with Temperature Chamber | |
Description | WKZT2-30 2 axis rate table with temperature chamber applies 2 axis U-T frame. It is able to do the multi-functional simulation test in condition of high and low temperature. It provides position, rate, swing, high and low temperature test etc.and meet the requirement of all functional tests and experiments for the inertial system and inertial parts. |
Main technical spec. | |
Payload | 30Kg |
Installation dimension of measured device | φ500mm×400mm |
Table's weight | About 700Kg |
Table surface dimension | φ530mm |
Table surface beating | 0.02mm |
Wobble error | ±2″ |
Axes verticality | ±3″ |
Rotational angle range: | Continuous, unlimited |
Operation mode | Position, rate, swing |
Slip ring | User's slip ring(customized number and power) |
Electrical control cabinet | Standard cabinet |
Computer system | Industrial control computer,Windows interface,RS422,Ethernet(≥100Mbps), Receiving pulse synchronized signal(≥100Hz), 1°,10°,360° pulse output |
Safety precaution | Real-time display system status and safety protection status, take fault tolerance checking for command to prevent misoperation. |
Amibient temperature | 20℃±5℃ |
Angular position measuring accuracy | ±2″ |
Angular position measuring resolution | 0.36″ |
Angular position measuring repeatability | ±1″ |
Angular position control accuracy | ±2″ |
Rate range | Inner axis:±0.001°/s~600°/s;outer axis ±0.001°/s~300°/s |
Rate accuracy and stability | 0.00003(360° average) |
Maximum acceleration | Inner axis:500°/s2;outer axis200°/s2 |
Swing data | Period0.1s~50s,amplitude±50° |
Internal dimension of temperature chamber | 550mm(W)×600mm(W)×520mm(H)(Effective height≥420mm) |
Temperature control range | -45℃~+70℃(Capability range -55℃~+70℃) |
Temperature control accuracy and uniformity | ±1℃(Empty chamber) |
Temperature lift rate | 1℃/min~2℃/min |
Driver mode | Torque motor direct driver |