Add to Cart
Single-Axis Rate And Position Tables
In Some Applications, The Requirement Is To Provide Stimuli In The Form Of Angular Rates, Accelerations And Positions Around One Pivotal Point To Devices Like Gyroscopes, Accelerometers, Or Inertial Measurement Units (Imus). For Such Cases, Acutronic One-Axis Tables Or Rotary Stages Are The Right Choice.
The Wide Range Of Potential Customer Specifications Is Accommodated By A Number Of Standardized Or Customized Tables And Rotary Stages. They Are Distinguished By Differing Electrical Drive Technologies (Direct Drive, Belt Drive), Table Tops, Motion Controllers (Cots, Acutrol®3000e), And Various Options (Table Tops, Temperature Chambers, Accessories And Sliprings).
WKZT-40 Single Axis Rate Table with Temperature Chamber | |
Description | WKZT-40 single axis rate table with temperature chamber is able to do the multi-functional simulation test in condition of high and low temperature. It provides position, rate, swing, high and low temperature test etc.and meet the requirement of all functional tests and experiments for the inertial system and inertial parts. |
Main technical spec. | |
Payload | 40Kg |
Installation dimension of measured device | φ400mm×400mm |
Table's weight | About 400Kg |
Table surface dimension | φ430mm |
Table surface flatness | 0.01mm |
Table surface beating | 0.02mm |
Table surface residule magnetism | <0.2mT(1cm above table surface) |
Wobble error | ±2″ |
Rotational angle range | Continuous, unlimited |
Operation mode | Position, rate, swing |
Slip ring | User's slip ring(customized number and power) |
Electrical control cabinet | Standard cabinet |
Computer system | Industrial control computer,Windows interface,RS422,Ethernet(≥100Mbps), Receiving pulse synchronized signal(≥100Hz) |
Safety precaution | Real-time display system status and safety protection status, take fault tolerance checking for command to prevent misoperation. |
Amibient temperature | 10℃~40℃ |
Angular position measuring accuracy | ±1″ |
Angular position measuring resolution | 0.36″ |
Angular position measuring repeatability | ±2″ |
Angular position control accuracy | ±1″ |
Rate range | ±0.001°/s~600°/s |
Maximum acceleration | 150°/s2 |
Swing data | Period 0.1s~50s,amplitude ±50° |
Internal dimension of temperature chamber | 500mm(W)×500mm(W)×500mm(H) |
Temperature control range | -55℃~+80℃ |
Temperature control accuracy and uniformity | ±1℃(Empty chamber) |
Temperature lift rate | 1℃/min~2℃/min |
Driver mode | Torque motor direct driver |